Home ProductsSuppliersNews ServiceContact usAbout us Sign InJoin FreeTrade shows
Welcome to TradingChem
Current position:Home > Products > 4-Bromomethyl-3-nitrobenzoic acid

CAS No.:55715-03-2

Name: 4-Bromomethyl-3-nitrobenzoic acid

Details Introduction

TOXICITY DATA with REFERENCE:Acute toxicity:
Primary irritant effect:
on the skin:
Corrosive effect on skin and mucous membranes.
Irritating effect.
Lachrymatory effect.
Sensitization: No sensitizing effects known.
Subacute to chronic toxicity:
Corrosive materials are acutely destructive to the respiratory tract, eyes, skin and digestive tract. Eye contact may result in permanent damage and complete vision loss. Inhalation may result in respiratory effects such as inflammation, edema, and chemical pneumoitis. May cause coughing, wheezing, laryngities, shortness of breath, headache, nausea and vomiting. Ingestion may cause damage to the mouth, throat and esophagus. May cause skin burns or irritation depending on the severity of the exposure.
SAFETY PROFILE:
Hazard Symbols: C
Risk Phrases:
R 34 Causes burns.
Safety Phrases:
S 25 Avoid contact with eyes.
S 36/37/39 Wear suitable protective clothing, gloves and eye/face protection.
S 45 In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible).
WGK (WATER Danger/Protection)

Standards and Recommendations:ASSAY OF 4-(BROMOMETHYL)-3-NITROBENZOIC ACID: 97%

Analytical Methods:For analytical separations an Abimed (D-Langenfeld) HPLC system is used consisting of 2 pump units 306, a dynamic mixing chamber module 811C, a manometric pressure module 805, an UV-Detector UV/VIS 155 and an autoinjector 234.  A gradient of H2O/0.1% TFA (v/v) (eluent A) and acetonitrile/0.1% TFA (v/v) (eluent B) with a flow rate of 0.4 mL/minutes is used. UV-traces are measured at λ=214 and λ=305 nm, respectively. An analytical column GromSil120 ODS-5 ST (3 μm, 60×2 mm) manufactured by Grom (D-Herrenberg) is used. A gradient of H2O/0.1% TFA (v/v) (eluent A) and acetonitrile/0.1% TFA (v/v) (eluent B) with a flow rate of 0.6 mL/minutes is used.d) Preparative HPLC: For preparative separations an Abimed (D-Langenfeld) HPLC system 1014 is used consisting of a pump unit 322, an UV-Detector UV/VIS 151 (quadrature=305 nm) and a Gilson 215 Liquid-Handler. The separation is performed on a preparative column Purospher RP18 (5 μm, 125×25 mm) manufactured by Merck (D-Darmstadt).

Related Searches

Urgent Purchase
About us | Contact us | Service | Link | Make Me Home Page | Add to favorite|Chemical industry exhibitions |Sitemap
Copyright 2010 TradingChem Group Ltd.
All Rights Reserved. No Unauthorized Reproduction or Duplication of Any Kind.
Zhejiang 16009103